In this study, characterization of an automatic greenhouse spraying system containing a full cone spray nozzle is\npresented. Spray flow rate of the nozzle as a function of incoming pressure to the nozzle, together with distribution of mean\ndrop size, two components of drop velocity and uniformity of the generated spray are given in this study. Based on the results\nobtained, mean droplet size at the centreline of the spray is much smaller than dose in the outer side of the full cone spray.\nUniformity of the generated spray by a given nozzle should be examined before application, especially if the nozzle is not new.\nThe average generated drop size by the examined nozzle is less than 60 �µm which is suitable for the insecticide or fungicide\napplications.